{"id":37787,"date":"2017-10-04T13:54:00","date_gmt":"2017-10-04T11:54:00","guid":{"rendered":"https:\/\/cetec.co.at\/en\/?p=37787"},"modified":"2025-06-13T13:57:47","modified_gmt":"2025-06-13T11:57:47","slug":"ethernet-cable-preparation","status":"publish","type":"post","link":"https:\/\/cetec.co.at\/en\/ethernet-cable-preparation\/","title":{"rendered":"Ethernet-Cable Preparation"},"content":{"rendered":"\n<p>Data Communication Technology in cars or automobiles is a challenge, which the Automotive Industry tries to accommodate with ever new and optimized ways.<\/p>\n\n\n\n<p>The current trend leads to&nbsp;<strong>data transfer via ethernet cable<\/strong>. A solution, that guarantees a&nbsp;<strong>satisfying data communication<\/strong>. Due to the cables smaller cross-sections, ethernet further supports the challenging weight matter of the interior material.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"450\" height=\"600\" src=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3-fachHub1.jpg?_t=1747915213\" alt=\"\" class=\"wp-image-37789\" style=\"width:355px;height:auto\" srcset=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3-fachHub1.jpg 450w, https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3-fachHub1-345x460.jpg 345w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><figcaption class=\"wp-element-caption\">Crimping Unit<\/figcaption><\/figure>\n<\/div>\n\n\n<p>To ensure a&nbsp;<strong>safe and reliable cable preparation<\/strong>, the whole process calls for appropriate and suitable technology, both at the tools and at the press. Hereby typical challenges are the seizing or&nbsp;<strong>gripping of the small cables<\/strong>, as well as&nbsp;<strong>process reliability with large quantities<\/strong>.<\/p>\n\n\n\n<p>Our experience shows, that even plastic-sheathed cables with a very small cross section, e.g. a cross section of 0.13 mm\u00b2, can be processed without problems.<\/p>\n\n\n\n<p>The use of a semi-automated crimping unit brilliantly carries out the process steps&nbsp;<strong>Zero Cut \u2013 Stripping \u2013 Crimping \u2013 Crimp Force Monitoring<\/strong>&nbsp;as well as&nbsp;<strong>Waste Cutting<\/strong>, especially when processing large batches.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Which process steps are possible using a crimping unit system?<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"414\" height=\"585\" src=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ehternet-2adrig.jpg?_t=1747915195\" alt=\"\" class=\"wp-image-37788\" style=\"width:198px;height:auto\" srcset=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ehternet-2adrig.jpg 414w, https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ehternet-2adrig-326x460.jpg 326w\" sizes=\"auto, (max-width: 414px) 100vw, 414px\" \/><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\">1 | Zero Cut:<\/h4>\n\n\n\n<p>In this step both wires will be cut to the same length.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2 | Stripping:<\/h4>\n\n\n\n<p>Both wires will be dismantled at once.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">3 | Crimping:<\/h4>\n\n\n\n<p>Both wires will be crimped.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">4 | Monitoring:<\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"585\" src=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3fach-Hub.jpg?_t=1747915223\" alt=\"\" class=\"wp-image-37790\" style=\"width:397px;height:auto\" srcset=\"https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3fach-Hub.jpg 600w, https:\/\/cetec.co.at\/en\/wp-content\/uploads\/sites\/2\/cetec-systems-Ethernet-3fach-Hub-460x449.jpg 460w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<p>The wire crimping process gets monitored and faulty crimps get detected, using a<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">5 | Waste Cut Module:<\/h4>\n\n\n\n<p>faulty crimps get separated from good crimps.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>These 5 process steps will be completed within a cycle time of approx. 3 seconds altogether!<\/strong><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">What are the advantages of using a crimping unit for Ethernet Cable Preparation?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>One process for a 2-wire-cable<\/li>\n\n\n\n<li>Same length for both wires<\/li>\n\n\n\n<li>Contacts are in the same position<\/li>\n\n\n\n<li>Optimal preparation for housing tamper<\/li>\n\n\n\n<li>Consistent and guaranteed crimping quality even with high quantities<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Data Communication Technology in cars or automobiles is a challenge, which the Automotive Industry tries to accommodate with ever new and optimized ways. The current trend leads to&nbsp;data transfer via ethernet cable. A solution, that guarantees a&nbsp;satisfying data communication. Due to the cables smaller cross-sections, ethernet further supports the challenging weight matter of the interior &#8230; <a title=\"Ethernet-Cable Preparation\" class=\"read-more\" href=\"https:\/\/cetec.co.at\/en\/ethernet-cable-preparation\/\" aria-label=\"Read more about Ethernet-Cable Preparation\">Read more<\/a><\/p>\n","protected":false},"author":4,"featured_media":37685,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"editor_notices":[],"footnotes":""},"categories":[6],"tags":[],"class_list":["post-37787","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cable-preparation"],"acf":[],"_links":{"self":[{"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/posts\/37787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/comments?post=37787"}],"version-history":[{"count":4,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/posts\/37787\/revisions"}],"predecessor-version":[{"id":38462,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/posts\/37787\/revisions\/38462"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/media\/37685"}],"wp:attachment":[{"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/media?parent=37787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/categories?post=37787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cetec.co.at\/en\/wp-json\/wp\/v2\/tags?post=37787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}